(2017) Undesired Outcomes of the Catania Stent Compared to the Xience Stent in Patients Undergoing Angioplasty: A Double-Blind Randomized Controlled Trial. Advanced biomedical research. p. 154. ISSN 2277-9175 (Print) 2277-9175 (Linking)
Full text not available from this repository.
Abstract
Background: The present study tries to compare the unintended outcomes of the Catania stent versus Xience stent in patients undergoing angioplasty. Materials and Methods: In a three month, follow-up, double-blinded, randomized controlled trial, 83 patients undergoing angioplasty, who met the inclusion criteria were entered into the study. After randomization 43 patients were treated with the Xience stent and 40 patients with the Catania stent. Stent-related outcomes such as Cardiac and Non-Cardiovascular Death, Myocardial Infarction (MI), Target Lesion Revascularization (TLR), Stent Thrombosis (ST), Coronary Artery Bypass Grafting (CABG), Peripheral vasculopathy, and Cerebral Vascular Accident (CVA) were compared between the groups. Results: There was no statistically significant difference in the incidence rate of complications and clinical outcomes between the two treatment groups (P > 0.05). The incidence of MI, TLR, CABG operation, peripheral vasculopathy, or CVA was not observed in any patient and there was no statistically difference in mortality (4.7 vs. 2.5; P = 0.527) and stent thrombosis (2.3 vs. 2.5; P = 0.735). Conclusion: All in all, the present study could not find the significant differences between the Catania stent and Xience stent in terms of clinical outcomes during the follow-up period.
Item Type: | Article |
---|---|
Keywords: | Angioplasty Catania stent Xience stent clinical outcome stent thrombosis |
Divisions: | Cardiovascular Research Institute > Cardiac Rehabilitation Research Center Cardiovascular Research Institute > Isfahan Cardiovascular Research Center |
Page Range: | p. 154 |
Journal or Publication Title: | Advanced biomedical research |
Journal Index: | Pubmed |
Volume: | 6 |
Identification Number: | https://doi.org/10.4103/2277-9175.219419 |
ISSN: | 2277-9175 (Print) 2277-9175 (Linking) |
Depositing User: | مهندس مهدی شریفی |
URI: | http://eprints.mui.ac.ir/id/eprint/1121 |
Actions (login required)
View Item |