Comparison of Ventilator's Work of Breath Cased on Constant Flow Nasal CPAP Through Pressure Limited and Electronic Feedback Pressure Control Mechanisms in the Treatment of RDS in Neonates Weighing About 1000 Grams

(2019) Comparison of Ventilator's Work of Breath Cased on Constant Flow Nasal CPAP Through Pressure Limited and Electronic Feedback Pressure Control Mechanisms in the Treatment of RDS in Neonates Weighing About 1000 Grams. Iranian Journal of Pediatrics. p. 6. ISSN 2008-2142

[img]
Preview
Text
11374.pdf

Download (124kB) | Preview

Official URL: WOS:000504050800004

Abstract

Background: Continuous distending pressure (CDP) is considered as standard care in neonates with decreased pulmonary compliance. Concerns regarding the implementation of non-invasive CDP in a respiratory cycle in order to establish an optimal level of functional residual capacity (FRC) abound in the related literature. Examples include how to manage gas leakage in the interface, no imposed increased work of breath (WOB) on patients and prevention of applying trans-pulmonary pressure levels leading to metabolic acidosis. Following the development of autoflow hardware, pressure control (PC) respiratory pattern was defined in the field of mechanical ventilation (MV) in order to compensate for gas leakage in interface or compensate for pressure drop and increased CDP pressure level in respiratory phases of inspiration and expiration. Objectives: The study aimed at decreasing WOB in neonates with RDS using pressure control-nCPAP. Methods: This study was a retrospective clinical trial performed on 70 neonates weighing about 1000 grams with RDS. Participants were randomly assigned into two respiratory support groups based on the use of pressure limited nCPAP (PL-nCPAP) and pressure control nCPAP (PC-nCPAP). Each group consisted of 35 infants compared in terms of their demographic characteristics, duration of non-invasive respiratory support, rapid shallow breathing (RSB) index, ventilator's WOB, need for MV, need for surfactant administration, chronic lung diseases, pneumothorax, intra-ventricular hemorrhage (IVH) and death. Results: No significant difference was observed between the mean time of non-invasive respiratory support and the need for MV, between the incidence of pneumothorax and IVH and also between the mortality rate and degree of involvement in chronic lung diseases in the two groups. The mean respiratory ventilation rate of ventilator's WOB in PC-nCPAP group was significantly higher than that of PL-nCPAP group. The mean RSB index was also significantly higher in PL-nCPAP group than in PC-nCPAP group. Finally, the mean of surfactant administration in PL-nCPAP group was significantly higher than that in PC-nCPAP group. Conclusions: In this study, ventilator's WOB in PC-nCPAP group, which was significantly higher than that of PL-nCPAP group, can be explained by significantly higher RSB index in PL-nCPAP group and significantly lower mean surfactant prescription in PC-nCPAP group.

Item Type: Article
Keywords: PC-nCPAP PL-nCPAP Pre-Term Neonates RDS positive airway pressure surfactant Pediatrics
Subjects: WS Pediatrics
Divisions: Faculty of Medicine > Departments of Clinical Sciences > Department of Pediatrics
Research Institute for Primordial Prevention of Non-communicable Disease > Child Growth and Development Research Center
Page Range: p. 6
Journal or Publication Title: Iranian Journal of Pediatrics
Journal Index: ISI
Volume: 29
Number: 6
Identification Number: https://doi.org/10.5812/ijp.91369
ISSN: 2008-2142
Depositing User: Zahra Otroj
URI: http://eprints.mui.ac.ir/id/eprint/11374

Actions (login required)