Electrocoagulation Accounts for a Significant Portion of Discrepancy Between Preoperative Ultrasonography Prostate Size Estimation and Resected Tissue Weight

(2020) Electrocoagulation Accounts for a Significant Portion of Discrepancy Between Preoperative Ultrasonography Prostate Size Estimation and Resected Tissue Weight. Journal of Endourology. pp. 671-675. ISSN 0892-7790

Full text not available from this repository.

Abstract

Background and Objectives: Transurethral resection of the prostate (TURP) is considered to be the gold standard surgical procedure for medium-sized prostates. However, there is a drastic difference between the weight of resected tissue reported by the pathologist and the sonographic estimate of prostate weight before the operation. The present study investigates the role of electrocoagulation in tissue loss during monopolar (M-) and bipolar (B-) TURP. Methods: In this experimental in vitro study, 33 prostate glands removed from patients by open suprapubic prostatectomy were roughly divided in half and the weight of each half was recorded precisely. One half of the specimen was resected using a monopolar resectoscope and the other half was resected by bipolar resectoscope in an out-of-body simulated condition. The weight of obtained chips was measured and the amount of lost tissue was calculated. Data from prostates with final pathologic diagnosis of benign prostatic hyperplasia were included in the analysis. The mean difference of prostate weight before and after out-of-body resection and also the proportion of tissue loss between M-TURP and B-TURP were compared using t-test. Results: Data from 62 prostate halves were included in the final analysis. The mean weight of samples after M-TURP was considerably lower than before resection (38.0 +/- 6.9 and 48.7 +/- 9.0, respectively, p < 0.001). Similarly, the mean weight of prostate samples after B-TURP was lower than the weight before resection (36.2 +/- 7.3 and 48.4 +/- 9.1, respectively, p < 0.001). However, the ratio of tissue loss in B-TURP (25.3 +/- 2.5) was significantly higher than in M-TURP (21.3 +/- 3.7) (p < 0.001). Conclusion: Prostate resection using electrocoagulation leads to a significant prostate tissue loss due to heat effect. Furthermore, tissue loss in B-TURP is slightly more than M-TURP.

Item Type: Article
Keywords: benign prostatic hyperplasia prostatectomy prostate transurethral resection pathology measurement BIPOLAR TRANSURETHRAL RESECTION TRANSRECTAL ULTRASOUND COAGULATION DEPTH TRANSITION ZONE MONOPOLAR VOLUME HYPERPLASIA TURP
Subjects: WJ Urogenital System
Divisions: Faculty of Medicine > Departments of Clinical Sciences > Department of Urology
Isfahan Kidney Transplantation Research Center
Page Range: pp. 671-675
Journal or Publication Title: Journal of Endourology
Journal Index: ISI
Volume: 34
Number: 6
Identification Number: https://doi.org/10.1089/end.2020.0037
ISSN: 0892-7790
Depositing User: Zahra Otroj
URI: http://eprints.mui.ac.ir/id/eprint/12988

Actions (login required)

View Item View Item