(2023) Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials. Bmc Oral Health. p. 7. ISSN 1472-6831
Full text not available from this repository.
Abstract
BackgroundThe accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) using conventional and scannable polyvinyl siloxane impression materials.MethodsTen patients were selected to replace the lateral teeth with a three-unit monolithic zirconia bridge. For each patient, in the first group, an impression was made with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). In the identical session, as the second group, an impression of conventional putty-wash polyvinyl siloxane was taken (BONASIL A(+) Putty; DMP, Greece). The marginal discrepancy was measured through the replicas, which were cut perpendicularly within the buccolingual and mesiodistal directions. An Independent t-test was employed for data analyses (P < 0.05).ResultsThe marginal discrepancy in a conventional method for central abutment in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method but it was not significant (P > 0.05). Also, the marginal discrepancy for canine abutment in the conventional method was higher than in the scannable method, but it was not significant, either (P > 0.05).ConclusionsFPDs fabricated from both scannable and conventional impression materials were not superior to each other in marginal fit for both central and canine abutments by evaluation using the replica technique.
| Item Type: | Article |
|---|---|
| Keywords: | Marginal fit Monolithic zirconia FPD Scannable impression materials-conventional impression material fixed dental prostheses all-ceramic crowns internal fit accuracy precision trueness silicone strength scanner Dentistry, Oral Surgery & Medicine |
| Page Range: | p. 7 |
| Journal or Publication Title: | Bmc Oral Health |
| Journal Index: | ISI |
| Volume: | 23 |
| Number: | 1 |
| Identification Number: | https://doi.org/10.1186/s12903-023-02771-z |
| ISSN: | 1472-6831 |
| Depositing User: | خانم ناهید ضیائی |
| URI: | http://eprints.mui.ac.ir/id/eprint/25698 |
Actions (login required)
![]() |
View Item |


