Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials

(2023) Clinical evaluation of marginal fit of uncemented CAD-CAM monolithic zirconia three-unit restorations in anterior areas, using scannable and conventional polyvinyl siloxane impression materials. Bmc Oral Health. p. 7. ISSN 1472-6831

Full text not available from this repository.

Abstract

BackgroundThe accuracy of impression techniques determines the marginal fit of fixed prostheses. Marginal accuracy plays a main role in the success and failure of treatments. This in-vivo study evaluated the marginal fit of anterior three-unit monolithic zirconia fixed partial dentures (FPDs) using conventional and scannable polyvinyl siloxane impression materials.MethodsTen patients were selected to replace the lateral teeth with a three-unit monolithic zirconia bridge. For each patient, in the first group, an impression was made with a two-step putty-wash technique using scannable polyvinyl siloxane material (BONASCAN; DMP, Greece). In the identical session, as the second group, an impression of conventional putty-wash polyvinyl siloxane was taken (BONASIL A(+) Putty; DMP, Greece). The marginal discrepancy was measured through the replicas, which were cut perpendicularly within the buccolingual and mesiodistal directions. An Independent t-test was employed for data analyses (P < 0.05).ResultsThe marginal discrepancy in a conventional method for central abutment in mid-buccal, mid-lingual, mid-mesial, and mid-distal was higher than in the scannable method but it was not significant (P > 0.05). Also, the marginal discrepancy for canine abutment in the conventional method was higher than in the scannable method, but it was not significant, either (P > 0.05).ConclusionsFPDs fabricated from both scannable and conventional impression materials were not superior to each other in marginal fit for both central and canine abutments by evaluation using the replica technique.

Item Type: Article
Keywords: Marginal fit Monolithic zirconia FPD Scannable impression materials-conventional impression material fixed dental prostheses all-ceramic crowns internal fit accuracy precision trueness silicone strength scanner Dentistry, Oral Surgery & Medicine
Page Range: p. 7
Journal or Publication Title: Bmc Oral Health
Journal Index: ISI
Volume: 23
Number: 1
Identification Number: https://doi.org/10.1186/s12903-023-02771-z
ISSN: 1472-6831
Depositing User: خانم ناهید ضیائی
URI: http://eprints.mui.ac.ir/id/eprint/25698

Actions (login required)

View Item View Item