The efficacy of hemiepiphysiodesis for idiopathic knee coronal angular deformity by reconstruction plate and screw: A pilot study

(2023) The efficacy of hemiepiphysiodesis for idiopathic knee coronal angular deformity by reconstruction plate and screw: A pilot study. Health Science Reports. p. 8.

Full text not available from this repository.

Abstract

BackgroundAngular deformities of the lower extremities are among the most common findings in pediatric orthopedics. Alteration of the mechanical axis in the lower extremity affects the cosmetic appearance and may lead to gait disturbances, knee discomfort, patellar maltracking with or without pain, and early joint osteoarthritis. In the current study, we aimed to investigate the efficacy of 3-hole 3.5 mm reconstruction plates in tension-band temporary hemiepiphysiodesis for correcting idiopathic knee coronal angular deformities. MethodsThe surgical procedure was performed using an extraperiosteal tension band plate (a 3-hole reconstruction plate) and two 3.5 mm cortical screws to treat idiopathic knee coronal angular deformity in children. The location of the hemiepiphysiodesis was determined based on the type of angular deformity present. Postoperative follow-ups were conducted through x-rays to measure the medial proximal tibial angle and lateral distal femoral angle of the limbs. Statistical analysis was then performed to evaluate the efficacy of the surgical treatment based on the rate of alignment change exhibited. ResultsThe study included 14 patients (25 limbs) with genu valgum deformity who underwent temporary hemiepiphysiodesis on both the distal femur and proximal tibia, with 16 proximal tibias and 15 distal femurs being corrected. The correction rate for genu valgum was found to be 0.59 degrees per month for both proximal tibial and distal femoral hemiepiphysiodesis. Six patients (12 limbs) were also identified with genu varum deformity, and the correction rates for proximal tibial lateral hemiepiphysiodesis and distal femoral lateral hemiepiphysiodesis were 0.85 degrees and 0.15 degrees per month, respectively. During a mean follow-up duration of 11 +/- 5.7 months, only one case of physeal plate closure was observed, and there were no other significant complications. ConclusionTemporary hemiepiphysiodesis with a 3-hole R-plate and two cortical screws takes advantage of physiological physeal growth to successfully treat idiopathic angular deformities with low complication rates.

Item Type: Article
Keywords: 3-hole R-plate angular deformity genu valgum genu varum hemiepiphysiodesis guided growth temporary hemiepiphysiodesis 8-plate epiphysiodesis modulation staples Public, Environmental & Occupational Health General & Internal Medicine
Page Range: p. 8
Journal or Publication Title: Health Science Reports
Journal Index: ISI
Volume: 6
Number: 6
Identification Number: https://doi.org/10.1002/hsr2.1302
Depositing User: خانم ناهید ضیائی
URI: http://eprints.mui.ac.ir/id/eprint/26068

Actions (login required)

View Item View Item