(2023) Impact of using standard and high-resolution exposure modalities of cone-beam computed tomography (CBCT) system for dental implants dimension measurements. Advanced Biomedical Research. p. 5. ISSN 2277-9175
Full text not available from this repository.
Abstract
Background: This study aimed to analyze the effects of standard and high-resolution exposures on the diagnostic accuracy of CBCT in the evaluation of dental implant dimensions.Materials and Methods: A descriptive-analytical study was carried out on 40 dry human mandibles with appropriate ridge quality based on panoramic radiography. CBCT (Soredex, Cranex 3D, Finland) with a large field of view (FOV) and CMOS flat panel detector were used. CBCT with standard and a high resolution was performed in each mandible. Axial images, reconstructed by OnDemand 3D software, were processed to prepare cross-sectional images from the areas marked by gutta-percha, and then measured by a ruler with an accuracy of 0.01 millimeter in the computer. Measurements were recorded by two observers and the obtained data were compared with the real ones.Results: The results showed suitable repeatability in radiologic measurements (r = 0.971), which is indicative of the high reliability of intraobserver measurement. The measurement of width with high-resolution exposure indicated a significant difference with the real condition (P < 0.001); however, this difference was not significant in the case of standard resolution (P > 0.05). Measurement of height with high resolution showed a significant difference with the real condition in the right mandible (P = 0.04) and left mandible (P = 0.05); however, this difference was not significant in standard resolution (P > 0.05). Conclusion: Based on our findings, the standard CBCT resolution modality is suggested for dental implant images due to its higher accuracy than high-resolution methods for diagnosing the implant dimensions.
Item Type: | Article |
---|---|
Keywords: | Cone-beam CT dental implant maxillofacial radiology resolution digital volume tomography linear measurements accuracy ct ultrasonography Research & Experimental Medicine |
Page Range: | p. 5 |
Journal or Publication Title: | Advanced Biomedical Research |
Journal Index: | ISI |
Volume: | 12 |
Number: | 1 |
Identification Number: | https://doi.org/10.4103/abr.abr₃₈₆₂₁ |
ISSN: | 2277-9175 |
Depositing User: | خانم ناهید ضیائی |
URI: | http://eprints.mui.ac.ir/id/eprint/26689 |
Actions (login required)
![]() |
View Item |