(2024) Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters. Physical and Engineering Sciences in Medicine. pp. 1513-1524. ISSN 2662-4729
Full text not available from this repository.
Abstract
The stability of dosiomics features (DFs) and dose-volume histogram (DVH) parameters for detecting disparities in helical tomotherapy planned dose distributions was assessed. Treatment plans of 18 prostate patients were recalculated using the followings: field width (WF) (2.5 vs. 5), pitch factor (PF) (0.433 vs. 0.444), and modulation factor (MF) (2.5 vs. 3). From each of the eight plans per patient, ninety-three original and 744 wavelet-based DFs were extracted, using 3D-Slicer software, across six regions including: target volume (PTV), pelvic lymph nodes (PTV-LN), PTV + PTV-LN (PTV-All), one cm rind around PTV-All (PTV-Ring), rectum, and bladder. For the resulting DFs and DVH parameters, the coefficient of variation (CV) was calculated, and using hierarchical clustering, the features were classified into low/high variability. The significance of parameters on instability was analyzed by a three-way analysis of variance. All DF's were stable in PTV, PTV-LN, and PTV-Ring (average CV (CV) <= 0.36). Only one feature in the bladder (CV = 0.9), rectum (CV = 0.4), and PTV-All (CV = 0.37) were considered unstable due to change in MF in the bladder and WF in the PTV-All. The value of CV for the wavelet features was much higher than that for the original features. Out of 225 unstable wavelet features, 84 features had CV >= 1. The CVs for all the DVHs remained very small (CV< 0.06). This study highlights that the sensitivity of DFs to changes in tomotherapy planning parameters is influenced by the region and the DFs, particularly wavelet features, surpassing the effectiveness of DVHs.
| Item Type: | Article |
|---|---|
| Keywords: | Dosiomics Field width Modulation factor Pitch Helical tomotherapy Prostate cancer Radiotherapy Engineering Radiology, Nuclear Medicine & Medical Imaging |
| Page Range: | pp. 1513-1524 |
| Journal or Publication Title: | Physical and Engineering Sciences in Medicine |
| Journal Index: | ISI |
| Volume: | 47 |
| Number: | 4 |
| Identification Number: | https://doi.org/10.1007/s13246-024-01463-4 |
| ISSN: | 2662-4729 |
| Depositing User: | خانم ناهید ضیائی |
| URI: | http://eprints.mui.ac.ir/id/eprint/29481 |
Actions (login required)
![]() |
View Item |


