Do metal artifact reduction algorithms influence the detection of implant-related injuries to the inferior alveolar canal in CBCT images?

(2024) Do metal artifact reduction algorithms influence the detection of implant-related injuries to the inferior alveolar canal in CBCT images? Bmc Oral Health. p. 7. ISSN 1472-6831

Full text not available from this repository.

Abstract

BackgroundThe routine application of dental implants for replacing missing teeth has revolutionized restorative and prosthetic dentistry. However, cone beam computed tomography (CBCT) evaluations of structures adjacent to the implants are limited by metal artifacts. There are several methods for reducing metal artifacts, but this remains a challenging task. This study aimed to examine the effectiveness of metal artifact reduction (MAR) algorithms in identifying injuries of implants to the inferior alveolar canal in CBCT images.MethodIn this in vitro study, mono-cortical bone windows were created and the inferior alveolar canal was revealed. Using 36 implants, pilot drill and penetration damage of the implant tip into the canal was simulated and compared to the control implants with distance from the canal. CBCT images were evaluated by four experienced observers with and without the MAR algorithm and compared to direct vision as the gold standard. The values of accuracy, sensitivity, and specificity were obtained and compared by receiver operating characteristic (ROC) curve (alpha = 0.05).ResultThe area under the ROC curve values for detection of pilot drill injuries varied between 0.840-0.917 and 0.639-0.854 in the active and inactive MAR conditions, respectively. The increase in ROC area was only significant for one of the observers (P = 0.010). For diagnosing penetrative injuries, the area under the ROC curve values was between 0.990-1.000 and 0.722-1.000 in the active and inactive MAR conditions, respectively. The improvement of ROC curve values in active MAR mode was only significant for one of the observers (P = 0.006).ConclusionActivation of MAR improved the diagnostic values of CBCT images in detecting both types of implant-related injuries to the inferior alveolar canal. However, for most observers, this increase was not statistically significant.

Item Type: Article
Keywords: Cone beam computed tomography Dental implant Inferior alveolar canal Metal beam computed-tomography Dentistry, Oral Surgery & Medicine
Page Range: p. 7
Journal or Publication Title: Bmc Oral Health
Journal Index: ISI
Volume: 24
Number: 1
Identification Number: https://doi.org/10.1186/s12903-024-04043-w
ISSN: 1472-6831
Depositing User: خانم ناهید ضیائی
URI: http://eprints.mui.ac.ir/id/eprint/29797

Actions (login required)

View Item View Item