The effect of implant angulation and splinting on stress distribution in implant body and supporting bone: A finite element analysis

(2015) The effect of implant angulation and splinting on stress distribution in implant body and supporting bone: A finite element analysis. European journal of dentistry. pp. 311-8. ISSN 1305-7456 (Print)

Full text not available from this repository.

Abstract

OBJECTIVE: The aim of this study was to investigate the influence of implant crown splinting and the use of angulated abutment on stress distribution in implant body and surrounding bone by three-dimensional finite element analysis. MATERIALS AND METHODS: For this study, three models with two implants at the site of mandibular right second premolar and first molar were designed (1): Both implants, parallel to adjacent teeth, with straight abutments (2): Anterior implant with 15 mesial angulations and posterior implant were placed parallel to adjacent tooth, (3): Both implants with 15 mesial angulations and parallel to each other with 15 degrees angulated abutments. Restorations were modeled in two shapes (splinted and nonsplinted). Loading in tripod manner as each point 50 N and totally 300 N was applied. Stress distribution in relation to splinting or nonsplinting restorations and angulations was done with ABAQUS6.13. RESULTS: Splinting the restorations in all situations, led to lower stresses in all implant bodies, cortical bone and spongy bone except for the spongy bone around angulated first molar. Angulated implant in nonsplinted restoration cause lower stresses in implant body and bone but in splinted models more stresses were seen in implant body in comparison with straight abutment (model 2). Stresses in nonsplinted and splinted restorations in cortical bone of angulated molar region were more than what was observed in straight molar implant (model 3). CONCLUSION: Implant restorations splinting lead to a better distribution of stresses in implant bodies and bone in comparison with nonsplinted restorations, especially when the load is applied off center to implant body. Angulations of implant can reduce stresses when the application of the load is in the same direction as the implant angulation.

Item Type: Article
Keywords: Angulated abutment dental implant finite element analysis
Page Range: pp. 311-8
Journal or Publication Title: European journal of dentistry
Journal Index: Pubmed
Volume: 9
Number: 3
Identification Number: https://doi.org/10.4103/1305-7456.163235
ISSN: 1305-7456 (Print)
Depositing User: مهندس مهدی شریفی
URI: http://eprints.mui.ac.ir/id/eprint/5566

Actions (login required)

View Item View Item