Evaluation of the photon dose calculation accuracy in radiation therapy of malignant pleural mesothelioma

(2018) Evaluation of the photon dose calculation accuracy in radiation therapy of malignant pleural mesothelioma. Journal of Cancer Research and Therapeutics. pp. 1029-1035. ISSN 0973-1482

Full text not available from this repository.

Abstract

Background: Photon dose distribution of malignant pleural mesothelioma (MPM) in matched photon-electron technique is influenced by media inhomogeneity, lateral electronic disequilibrium at interfaces and narrow field. These may influence the dose calculation accuracy, calculated by treatment planning systems (TPS). This study aimed to evaluate the dose calculation accuracy of TiGRT TPS in radiation therapy of MPM. Materials and Methods: 18 MV photon beams of ONCOR Siemens linear accelerator was simulated using EGSnrc Monte Carlo (MC) code. Data of four patients were used to compare TPS and MC results in different regions included: Open and in-field, under shied and out of field regions. Results: Compared to MC results, the TPS overestimated the pleura dose coverage (90 of prescribed dose) about 3-12 mm, and also it overestimated the dose in under the shielded regions of lung (4-74). While the TPS underestimated the dose profile width about 1-16 mm in low dose region (<50 prescribed dose) as well as the out of field region dose (4-100). Conclusions: Results showed that TPS underestimated the dose in out of field and overestimated the dose in under the shielded regions. Unlike MC measurements, TPS calculation showed adequate pleural dose coverage. Based on the results, MC calculation can be used in matched photon-electron beam radiation therapy of MPM to modify the TPS photon dose calculations in the presence of heterogeneity, interfaces, and shield in MPM radiotherapy.

Item Type: Article
Keywords: egsnrc monte carlo code inhomogeneity malignant pleural mesothelioma radiation therapy tigrt external-beam radiotherapy treatment planning systems monte-carlo air cavities 6 mv lung equilibrium algorithms simulation media
Divisions: Faculty of Medicine > Department of Basic Science > Department of Medical Physics
Page Range: pp. 1029-1035
Journal or Publication Title: Journal of Cancer Research and Therapeutics
Journal Index: ISI
Volume: 14
Number: 5
Identification Number: https://doi.org/10.4103/0973-1482.187284
ISSN: 0973-1482
Depositing User: Zahra Otroj
URI: http://eprints.mui.ac.ir/id/eprint/9474

Actions (login required)

View Item View Item