(2022) Internal and Marginal Fit Accuracy of Pre-sintered CAD/CAM Implant-Supported Frameworks Before and After Porcelain Layering. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS. pp. 601-607. ISSN 0882-2786 1942-4434 J9 - INT J ORAL MAX IMPL
Full text not available from this repository.
Abstract
Purpose: Internal and marginal fit accuracy of an implant-supported fixed partial denture (I-FPD) along with passive fit are required for long-term clinical success. This study compared the fit accuracy of three-unit CAD/CAM-fabricated cement retained I-FPDs milled from pre-sintered cobalt-chromium (Co-Cr) and zirconia (Zr) and evaluated the effect of applying porcelain. Materials and Methods: Two implant analogs were positioned parallel at first premolar and first molar sites in an acrylic model. Their corresponding abutments were tightened with 25-Ncm torque force. Four groups were designed: two groups of I-FPD frameworks with pre-sintered Zr (ZrF) and soft millable Co-Cr alloy (SF) blocks, and two groups by applying porcelain to the Co-Cr (SP) and Zr (ZrP) frameworks (n =4 in each group). Absolute marginal gap (AMG), marginal gap (MG), and internal discrepancies were measured. Kolmogorov-Smirnov, Levene, one-way analysis of variance (ANOVA), and Scheffe tests were used for statistical analysis using SPSS software version 22 at a significance level of .05. Results: All measured criteria were significantly different from each other (all P values <.001). The rankings from the lowest gap to the highest gap for the main criteria were as follows: MG: SF < SP < ZrF < ZrP; AMG and internal discrepancies: SF < SP < ZrP < ZrF. Comparing molars and premolars, molars had smaller MGs, larger internal discrepancies, and smaller AMG in ZrP but larger AMG in SP. Conclusion: All three-unit CAD/CAM-fabricated cement-retained I-FPDs were in the clinically acceptable range of fit accuracy. The lowest and highest misfit values were observed in the SF and ZrF groups, respectively. IntOOral Maxillofac Implants 2022;37:601-607. doi: 10.11607/jomi.8413
Item Type: | Article |
---|---|
Keywords: | cobalt-chromium computer-aided design and computer-aided manufacturing fixed dental prosthesis marginal gap pre-sintered materials zirconia FIXED DENTAL PROSTHESES CLINICAL SUCCESS METAL ADAPTATION DISCREPANCIES SURVIVAL SYSTEMS CROWNS |
Page Range: | pp. 601-607 |
Journal or Publication Title: | INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS |
Journal Index: | ISI |
Volume: | 37 |
Number: | 3 |
Identification Number: | https://doi.org/10.11607/jomi.8413 |
ISSN: | 0882-2786 1942-4434 J9 - INT J ORAL MAX IMPL |
Depositing User: | Zahra Otroj |
URI: | http://eprints.mui.ac.ir/id/eprint/16016 |
Actions (login required)
View Item |