(2021) Effect of multiple firings on the shear bond strength of presintered cobalt-chromium alloy and veneering ceramic. JOURNAL OF PROSTHETIC DENTISTRY. ISSN 0022-3913 1097-6841 J9 - J PROSTHET DENT
Full text not available from this repository.
Abstract
Statement of problem. How multiple firing cycles may affect the oxide layer and, consequently, the shear bond strength of metal-ceramic restorations is unclear. Purpose. The purpose of this in vitro study was to determine the effect of multiple firings on the shear bond strength of porcelain to cobalt-chromium (Co-Cr) alloy. Material and methods. Forty cylinders (circle divide 6.8x9 mm) of a representative presintered Co-Cr alloy (Ceramill Sintron) were prepared with computer-aided design and computer-aided manufacturing (CAD-CAM) technology. After airborne-particle abrasion and polishing, the specimens were ultrasonically cleaned of surface contaminants. A circular surface (circle divide 4x2 mm) was veneered on each specimen with porcelain (VM13) after 3 firings (wash opaque, opaque, and dentin). The specimens were then randomly divided into 4 groups (n=10). The normal group underwent 3 firings. The other groups underwent an additional porcelain firing: the one plus firing group underwent 4 firings, the two-plus firing group underwent 5 firings, and the three-plus firing group underwent 6 firings. Next, the specimens were mounted in autopolymerized acrylic resin and tested in a universal testing machine and loaded at a crosshead speed of 0.5 mm/min at the metal-ceramic interface until fracture occurred. The average shear bond strength (MPa) was calculated by dividing the maximum fracture force (N) by the bonded surface of the specimens (mm(2)). The fracture patterns were observed microscopically and classified as adhesive, cohesive, or mixed. One-way ANOVA was used to determine differences between groups (alpha=.05). Results. No significant differences were found among the shear bond strengths of specimens after 3, 4, 5, and 6 porcelain firings (P>.05). The mean bond strength of all groups ranged from 30 to 34 MPa. The fracture pattern of all specimens was mixed, indicating that multiple firings had no significant effect on the failure pattern. Conclusions. Multiple porcelain firings under controlled conditions had no significant effect on the fracture pattern or shear bond strength of porcelain to a presintered Co-Cr alloy.
Item Type: | Article |
---|---|
Keywords: | MECHANICAL-PROPERTIES PORCELAIN CAD/CAM |
Journal or Publication Title: | JOURNAL OF PROSTHETIC DENTISTRY |
Journal Index: | ISI |
Volume: | 126 |
Number: | 6 |
Identification Number: | https://doi.org/10.1016/j.prosdent.2021.09.021 |
ISSN: | 0022-3913 1097-6841 J9 - J PROSTHET DENT |
Depositing User: | Zahra Otroj |
URI: | http://eprints.mui.ac.ir/id/eprint/17317 |
Actions (login required)
View Item |