Influence of Metal Artifact Reduction Algorithms on the Detection of Inferior Alveolar Canal Perforations by Zirconia Implants in CBCT Images

(2026) Influence of Metal Artifact Reduction Algorithms on the Detection of Inferior Alveolar Canal Perforations by Zirconia Implants in CBCT Images. Clinical and Experimental Dental Research. p. 8. ISSN 2057-4347

Full text not available from this repository.

Abstract

Introduction This study aims to evaluate the efficacy of a metal artifact reduction (MAR) algorithm in detecting contact between zirconia implants and inferior alveolar canal. Materials and Methods Twelve zirconia implants were placed in dry human mandibles using surgical guides, in two conditions: 1 mm above and within the canal. cone beam computed tomography (CBCT) was acquired with the MAR algorithm turned off and on. Three observers indicated whether canal damage was present using a 5-point Likert scale: 1. Definitely no contact, 2. Probably no contact, 3. Uncertain, 4. Probably contact, and 5. Definitely contact. Sensitivity and specificity were calculated and the ROC curve was used to compare the two conditions (alpha = 0.05). Results The area under curve (AUC) was higher in MAR On condition for all observers; however, the differences in AUC between the On and Off MAR states were not statistically significant (p > 0.05): for observer 1, AUC increased from 0.9916 (Off) to 1.0 (On); for Observer 2, it increased from 0.7666 to 0.8833; and for Observer 3, it increased from 0.95 to 1.0. Observers 1 and 3 displayed 100 sensitivity and specificity regardless of MAR activation, while for Observer 2, diagnostic sensitivity increased from 66.7 to 83.3 with MAR activation, while specificity remained constant at 80 in both conditions. Conclusion For the detection of contact of the zirconia implants with the IAC, activating the MAR algorithm slightly increased the diagnostic performance metrics of CBCT images, but the differences were not statistically significant. Clinical Relevance Activating the MAR algorithm did not produce a statistically significant improvement in detecting contact between zirconia implants and the inferior alveolar canal.

Item Type: Article
Keywords: artifact cone beam computed tomography dental implant mandibular canal nerve injuries Dentistry, Oral Surgery & Medicine
Page Range: p. 8
Journal or Publication Title: Clinical and Experimental Dental Research
Journal Index: ISI
Volume: 12
Number: 4
Identification Number: https://doi.org/10.1002/cre2.70397
ISSN: 2057-4347
Depositing User: خانم ناهید ضیائی
URI: http://eprints.mui.ac.ir/id/eprint/34336

Actions (login required)